Hypertherm V9 Series Phoenix Rev.11 Manual do Utilizador Página 241

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 240
Phoenix 9.76.0 Installation and Setup Manual 806410 241
Section 12
Serial Ports
Hypertherm CNCs support two serial ports that can be set for either RS-422 or RS-232 communications. Both serial
ports are set to RS-422 at the factory. To change either serial port to RS-232, you must change a jumper setting on the
serial isolation board that is inside the CNC. The jumper positions are clearly marked on the board.
The serial ports in the CNC are specifically designed to operate with a standard nine-pin serial port connector. The
following table provides specifications for these ports:
CAUTION
Set the port for the chosen type of serial operation (RS-422 or RS-232) before connecting
compatible devices.
Channel Type Optically isolated RS-232C or RS-422
Information Code ASCII
Baud Rate User-selectable up to 115.2K baud
Number of Start Bits 1
Number or Stop Bits 1
Word Length User-selectable 7 or 8 bits
Parity User-selectable none, even or odd
Data Synchronization XON (Control-Q) / XOFF (Ctrl/S)
Time Out User-selectable in one-second increments
Transmit Delay User-selectable in 0.01-second increments
Rear Panel Connector IBM-PC/AT compatible 9-pin D-type female
Vista de página 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 293 294

Comentários a estes Manuais

Sem comentários